CONSTRUCTION CASE

TS Korea — Subway Station Septic Tank Hazardous Gas Detection: Pre-Work Checks Are Essential

Pyeongtaek · 2026.07.09

Applied Markets

Safety

Installed Gases

EX (Combustible) CO (Carbon Monoxide) O2 (Oxygen) H2S (Hydrogen Sulfide) CO2 (Carbon Dioxide)

End customer

Pyeongtaek Station

Project Details

  • Why Hazardous Gas Measurement Matters in Subway Station Septic Tanks

Subway station septic tanks sit inside heavily used public facilities, but the spaces where maintenance actually takes place are often underground, confined, and poorly ventilated. As sewage and organic matter decompose inside the tank, oxygen depletion, hydrogen sulfide, carbon dioxide, and combustible gases can all build up — making gas concentration checks before entry essential.

The most dangerous aspect of septic tank work is that the hazard is invisible. Even if the interior looks clean or odor is mild, oxygen levels may already be low or toxic gases like hydrogen sulfide may have accumulated. The moment a worker opens the manhole and enters, sudden dizziness, loss of consciousness, or asphyxiation can follow — making pre-entry measurement and continuous monitoring a mandatory safety practice, not an option.

  • A fixed FIX800 gas detector paired with a FIX-DS hazard gas display board is an effective solution for sites like this.

FIX800 can be permanently installed at septic tanks, underground pits, manholes, pump rooms, and other locations where hazardous gas may occur, continuously monitoring O2, CO, H2S, LEL, and CO2. Unlike a portable detector that a worker must carry in before checking conditions, FIX800 lets site conditions be assessed from outside the space, speeding up pre-work risk decisions.

The FIX-DS display board shows the gas concentrations measured by FIX800 in a location clearly visible to both workers and supervisors, covering oxygen deficiency, carbon monoxide, hydrogen sulfide, combustible gas, and carbon dioxide levels at a glance — supporting pre-work safety checks, ongoing monitoring, and emergency response.

  • This is especially valuable at sites like subway station septic tanks, where workers enter frequently and external supervisors must also verify conditions.

    Having a display board means internal gas concentrations can be read as concrete numbers rather than relying on a "should be fine" assumption — allowing go/no-go decisions to be based on objective data.

Managing subway station septic tank safety is far more effective when hazards are blocked before work begins, rather than responding after an incident occurs. Combining the FIX800 fixed detector with the FIX-DS display board provides continuous monitoring of hazardous gases inside the tank and rapid alerts to workers — an effective solution for preventing confined-space asphyxiation accidents.

  • For any site requiring hazardous gas management in confined spaces — septic tanks, manholes, wastewater treatment facilities, or underground pump rooms —

consider a fixed gas detection system capable of simultaneously monitoring all five key gases: O2, CO, H2S, LEL, and CO2.

CategoryDetails
Applicable sitesSubway station septic tanks, manholes, wastewater treatment facilities, underground pits, pump rooms
Key hazardsOxygen deficiency, hydrogen sulfide poisoning, carbon monoxide/carbon dioxide accumulation, combustible gas explosion risk
Gases measuredO2, CO, H2S, LEL, CO2
FIX800 advantageFixed installation enables continuous monitoring and pre-work risk verification
FIX-DS advantageGas concentrations visible at a glance from outside, viewable by workers and supervisors simultaneously
Expected benefitsAsphyxiation prevention, pre-work safety decisions, strengthened on-site safety management

<Installation Photos>

가스측정기 전문 완디코리아 WANDI®
가스측정기 전문 완디코리아 WANDI®
가스측정기 전문 완디코리아 WANDI®
가스측정기 전문 완디코리아 WANDI®
가스측정기 전문 완디코리아 WANDI®
가스측정기 전문 완디코리아 WANDI®

With the gas concentration display board installed before entry, staff can now confirm septic tank conditions in advance and work safely.

TS Korea provides consultation on hazardous gas detection and installation for confined spaces, septic tanks, wastewater treatment facilities, manholes, and more.

More installation case studies -> https://www.tskorea.kr/55