Hello from TS Korea. This note covers a GasTiger 2000 configured for propene (propylene, C3H6) leak surveys at a cylinder filling area.

We applied a calibrated VOC channel with a propene response factor of 1.4 (menu path: System → Administrator → Measurement → Display coefficient). The meter was preconfigured before shipment for faster field use.

VOC sensors ship with isobutylene span gas; default relative response is 1.0 until the customer-specific factor is entered—here 1.4 for propene service.

Need a different hydrocarbon curve? Contact TS Korea (032-522-7189, tskorea@tskorea.kr).