Raymond Korea Co., Ltd.
Active Case Registration PartnerGas detection construction cases performed by Raymond Korea Co., Ltd..
Raymond Korea Co., Ltd. Construction Cases
Fixed Gas Detector and Gas Concentration Display Board Installation — Power Plant Wastewater Treatment Room (Donghae)
Hello. This case introduces the installation of a fixed gas detector and an entrance gas concentration display board in
Confined-Space Gas Detectors and LED Display Boards — Large Hospital Installation (Ilsan)
Today's site is a set of confined spaces in a large hospital.A large hospital used by many people contains more confined
CO2 Fire Suppression Room Gas Monitoring — FIX800 O2/CO2 Detector and Entrance Gas Display Board at a Logistics Warehouse (Yongin)
Hello. Today's case is an installation inside a CO2 fire suppression room at a large logistics warehouse operated by a w
Oxygen (O2) Gas Detector Installation for Research Laboratories Using High-Pressure Gas Cylinders — National Science Institution (Incheon)
Hello. This is a review of a gas detector installation in the research laboratories of a science-related public institut
Gas Detector Installation Guide — Oxygen and Hydrogen Sulfide Monitoring for a Wastewater Treatment Room (Seoul)
This site is a wastewater treatment facility at a department store. First, we'd like to share KOSHA's (Korea Occupa
FIX800 Suction-Type Gas Detector for Coastal Wastewater and Waste Treatment Facility (Wando, Jeollanam-do)
This site is a public environmental corporation facility located near the coast, handling waste generated from the sea a
CO2 (Carbon Dioxide) Gas Alarm Installation — Fire-Suppressant Agent Room & Protection Zone (Donghae, Gangwon-do)
Hello. This case covers a CO2 fire-suppressant gas room and its protection zone. Since October 18, 2024, workplaces tha
O2/CO2 Gas Detector Installation — Cold Storage Warehouse Handling Dry Ice (Yongin, Gyeonggi-do)
Hello. This case covers a cold storage warehouse that handles dry ice. Dry ice is a material many of us encounter when
FIX800 Fixed Gas Detector (O2/H2S) — Wastewater Treatment Facility Inside a Power Plant (Chuncheon, Gangwon-do)
This case involves the installation of a fixed gas detector for confined-space monitoring at a wastewater treatment faci
Oxygen Detector Installation in a Halon Fire-Suppression Gas Room
Hello. This installation case involves a gas detector installed inside a fire-suppression gas room, and it has one parti
Selecting the Right Gas Sensor for Laboratory Cylinder Gases — Oxygen Detector Installation at a Research Institute (Incheon)
Hello. Today we're taking a look at a research and laboratory site — a change of pace from our usual wastewater treatmen
FIX800 Oxygen (O2) Gas Detector Installation in a Power Plant Server Room and Control Room
This site was a rather unusual case. We installed oxygen concentration detectors in the server room and control room in
Gas Detection Installation for Confined Spaces in a Department Store
Hello. Today's site is a department store.Working in gas detector sales, we're reminded of just how many different indus
Confined-Space Gas Detector Guide for General Hospitals — Wastewater Facilities, Fire Suppression Rooms, Boiler Rooms, and Generator Rooms (Ilsan, Gyeonggi-do)
Hospitals are among the facilities that matter most to human life — they treat illness and care for emergency patients.
Chlorine (Cl2) and Ammonia (NH3) Gas Detector Installation – Water Treatment Facility
Hello. This case covers the installation of gas detectors at a water treatment facility operated by an environment
FIX800 O2/CO2 Fixed Gas Detector and Remote Display Installation — Cold Storage Warehouse (Gimhae, Gyeongsangnam-do)
Hello. This site is a cold storage warehouse. We're often asked by facility managers whether a cold storage warehouse ac
Siheung, Gyeonggi-do Wastewater Treatment Plant — Fixed O₂/H₂S Gas Detector Installation
Siheung, Gyeonggi-do Wastewater Treatment Plant — Fixed O₂/H₂S Gas Detector Installation This case documents a gas detec
Seoul Public Institution Underground Septic Tank — Gas Detector Installation
Seoul Public Institution Underground Septic Tank — Gas Detector Installation The word "safety" has become central to vir
Nitrogen and Hazardous Gas Handling Company — Gas Detector Application Case
Nitrogen and Hazardous Gas Handling Company — Gas Detector Application Case This case documents a gas detector installat
CO₂ Detectors and Integrated Display Board for a Fire Suppression Agent Room and Protected Areas (Pyeongtaek)
This case covers the installation of gas detectors in a fire suppression gas room and its protected areas.Over the past
Gas Detector Application Case at Power Plant Wastewater Relay Pump Room (Bundang)
Power Plant Wastewater Relay Pump Room — Gas Detector Application Case (Bundang) This case documents a gas detector app
Methanol (LEL) Detector and Concentration Display Board at a Wastewater Treatment Plant Denitrification Facility (Daegu)
This site is a wastewater treatment plant, but it came with an unusual request compared with typical projects.At wastewa
FIX800 Oxygen/Hydrogen Gas Detectors and Display Boards for the National Ambient Air Monitoring Network — Nationwide Installation
This case covers the installation of gas detectors at ambient air monitoring stations located on the rooftops of communi
Gas Detector Installation at a Large Shopping Mall Septic Tank
Large Shopping Mall Septic Tank — Gas Detector Installation This case covers a gas detector installation at the septic
FIX800 Suction-Type Gas Detector Installation — Sump Pit and Manhole Confined-Space Monitoring (Gangwon-do)
This installation case introduces a site where a suction-type (pumped) gas detector was installed.First, it helps to und
FIX800 Multi-Gas Detector Installation — CH4 and H2S Monitoring at a Biomass Facility (Daegu)
This site is a biomass facility. A facility that produces biogas is called a biomass facility. Biogas is an alternative
FIX800 Oxygen Detector Installation — Automated Coating Line Safety at a Factory (Gyeonggi-do)
This installation introduces an oxygen concentration detector installed at a factory with an automation line.The company
FIX800 4-Gas Detector Installation — O2/CO/H2S/LEL Monitoring for a High-Rise Basement Sewage Treatment Room (Daejeon)
This site is a confined-space sewage treatment room in the basement of a large building.The sites we've introduced befor
FIX800 Nitrogen/Hydrogen Gas Detection — O2 and LEL Sensor Installation for a University Laboratory (Namyangju, Gyeonggi-do)
This site is a university laboratory that uses nitrogen and hydrogen gas.Nitrogen and hydrogen are gases used very frequ
FIX800 O2/CO2 Gas Detector Installation — Confined-Space Safety for a Cold Storage Warehouse (Anseong, Gyeonggi-do)
This site is a cold storage warehouse. Many people ask whether a space like this counts as a confined space. We can't ma
FIX800 O2/CO2 Detector Installation — Fire-Suppression Gas Room and Protected Area Monitoring per Revised Law (Seoul)
This installation is a gas detector case for a CO2 fire-suppression gas room and agent storage room.A CO2 fire-suppressi
FIX800 O2/CO/H2S/LEL Multi-Gas Detector Installation — Confined-Space Safety at a Food-Waste Treatment Facility (Paju, Gyeonggi-do)
This installation is a case for a food-waste treatment facility.Put simply, this kind of site processes food waste into
FIX800 Hydrogen Sulfide and Methane Gas Detector Installation — Confined-Space Septic Tank Safety (Pohang, Gyeongsangbuk-do)
This case study introduces a confined-space septic tank / simple septic tank installation.Septic tanks are found in near
FIX800 Oxygen and Hydrogen Sulfide Detector Installation — Wastewater Treatment Room Safety (Daegu)
This case study covers a wastewater treatment room installation.A wastewater treatment room (also called a septic tank r
FIX800 Multi-Gas Detector Installation — Cleanroom (O₂ / CO / H₂S / LEL)
This installation was carried out in a cleanroom. Cleanrooms are maintained under negative pressure to prevent externa
FIX800 ETO (Ethylene Oxide) Gas Detector Installation — Hospital Sterilization Room
This installation was carried out at a hospital ETO (ethylene oxide) sterilization room. Endoscopes and other reusabl
FIX800 CO₂ / O₂ Detector Installation in Fire Suppression Rooms — Regulation FAQ and Power Plant Case
This article shares field installation cases for CO₂ suppression room gas detectors — the most active project category t
FIX800 O₂ / CO₂ Detector Installation in Fire Suppression Agent Rooms — Revised Regulation Guide
This article covers the most frequently discussed topic of the year: gas detector installation in fire suppression agent
FIX800 Oxygen and CO₂ Monitoring Installation in Cold Storage Warehouses (Confined Space)
Hello. Today's case is an O₂ and CO₂ detector installation site — a type of installation we carry out on a regular basis
Gas Leak Detector Installation for Halon/CO2 Fire Suppression Agent Rooms — Nationwide
Hello. We occasionally receive inquiries about installing gas detectors in fire suppression agent rooms. Let us briefly
Nitrogen Gas Line Oxygen Concentration Detector Installation — Pyeongtaek
Hello. Today's installation site uses nitrogen gas to manufacture equipment and parts, and detectors were installed afte
Confined Space Hazardous Gas Detectors for Sewage Treatment, Machine, Boiler & Electrical Rooms — Nationwide
Hello. Today we've selected one of the most representative site cases that we frequently receive installation inquiries
FIX800 O₂ Detector and 3 Custom FIX_DS Display Boards — Nitrogen Leak Oxygen-Deficiency Prevention in a Semiconductor Equipment Manufacturer's Cleanroom (Pyeongtaek)
Hello. Today we visited a company that manufactures semiconductor equipment and carried out an installation. The company
FIX800 CO / O₂ Fixed Gas Detector — Indoor Air Quality Monitoring for School Cafeteria Kitchens (Nationwide)
Hello, this is our team. Today we'd like to introduce a fixed gas detector solution designed for school cafeteria kitche
GasTiger 2000 Portable Multi-Gas Detector Guide — 5-Gas Confined Space Measurement, Features, and Operation (Nationwide)
Hello. The product we introduce today is the GasTiger 2000 multi-gas detector for measurements in confined spaces. What
FIX800 H₂S/CH₄ Fixed Gas Detector and FIX_DS Display Board Installation — Dewatering Facility (Daejeon)
Hello. Product: FIX800 (fixed gas detector) The FIX800 can be fitted with sensors selected from a lineup of around 40 g
Plasma Gas Concentration Detector (NO, NO2) — Incheon
Hello. Today we'll explain a site where nitric oxide (NO) and nitrogen dioxide (NO2) were generated under plasma conditi
FIX800 O₂/CO/H₂S/CO₂ Fixed Gas Detector — Golf Course Wastewater Treatment Facility (Busan)
FIX800 Fixed Gas Detector — Golf Course Wastewater Treatment Facility (Busan) Hello. This case covers the installation
FIX800 Fixed Oxygen Detector — Laboratory Safety Installation for Nitrogen Gas Environment (Incheon)
FIX800 Fixed Oxygen Detector — Laboratory Installation for Nitrogen Gas Safety (Incheon) This article introduces the FI
GASTIGER2000 (GT2000) Portable Gas Concentration Detector — Changwon
Hello. Today we're introducing the GASTIGER2000, a product that can simultaneously measure the 4 key confined-space gase
Fixed Gas Detector Installation at a Department Store Water Tank Room — Nationwide
Hello. Today we'd like to share an installation case for fixed-type gas detectors installed in a water tank room and a f
Fixed Gas Detector Installation on a Dry Ice Production Line — Gwanggyo, Suwon
Hello. Today we'd like to introduce an installation case for a gas detector installed at a factory that produces dry ice
Fixed Hydrogen Leak Detector / Hydrogen Alarm Installation — Yongin
Hello. Today's site is a case where we installed a hydrogen leak detector inside a factory that uses hydrogen gas. The
Fixed CO2 Detector Installation in a Fire Suppression Gas Room — Seoul Metro Area
Hello. Today we're sharing an installation case for a fixed-type carbon dioxide detector in a fire suppression gas room.
Gas Sampling Pretreatment System for High-Temperature / High-Humidity Environments
Hello. Today we'd like to introduce a technique for measuring gas in environments exceeding 100°C in gas temperature, or
Oxygen Concentration Detector Installation at a Wastewater/Sewage Treatment Plant — Daejeon
Hello. Today's case is a gas detector installation at a sewage/wastewater treatment plant. The most common question we
Oxygen Detector & Display Board Monitoring System for Confined Spaces
Hello. We're sharing an installation case of an oxygen detector and display board monitoring system for confined spaces.
FIX800 Gas Detector Monitoring System Installation — Fire Suppression Gas Room
Hello. Today we'd like to introduce the FIX800 gas detector installed in a fire suppression gas room. The installation s
EtO (Ethylene Oxide) Sterilizer Gas Leak Detector Installation — Hwaseong Dongtan
Hello. We'd like to introduce an installation case of the FIX800 EtO (ethylene oxide) gas leak detector, one of our stea
Indoor Air Quality VOC Detector Delivery Case — Construction Site
Hello. Today we'd like to introduce a delivery case of a VOC (volatile organic compound) detector, used for indoor air q
Hydrogen Leak Detector Installation — Research Laboratory, Seoul
Hello. Today's topic is hydrogen gas, which is gaining spotlight in this eco-friendly era. Hydrogen is being highlighted
Confined-Space Oxygen Detector & Display Board Installation — Gyeongnam
Hello. Today we're introducing an installation case of an oxygen concentration detector used in a confined space. The si
Hydrofluoric Acid (HF) Gas Detection Technology — GasTiger3000
Hello. Today we're introducing hydrofluoric acid (HF) gas detection technology using the GasTiger3000, a model dedicated
Oxygen Concentration Detector Installation for Water Treatment, Wastewater, and Septic Tank Facilities
Hello. Today we're sharing an installation case for an oxygen detector at a septic tank chamber, part of our oxygen moni
FIX800 Fixed Multi-Gas Detector (O₂, CO, H₂S, EX) — Confined Space Safety Installation for Electrical, Boiler and Water Treatment Rooms (Nationwide)
Hello. Today's installation case covers a confined space hazardous gas detector.If you're wondering why gas detectors ar
FIX800 Gas Detector Monitoring System — Oxygen and CO₂ Concentration Management for Cold Storage Warehouse (Gyeonggi-do, Gyeongsang-do)
Hello. This is our team. Today we'd like to introduce a FIX800 gas detector installed at a cold storage warehouse, along
FIX800 Gas Detector Wireless AP Transmission System — 4-Gas (O2/CO/H2S/LEL) Monitoring for Tunnel Construction (Nationwide)
Tunnel construction where wireless signals don't reach... Hello. This is our team. During subway or tunnel construction,
FIX800 Ethylene Oxide (EtO) Gas Leak Detector Installation — Hospital Sterilizer Room (Gyeonggi-do, Jeolla-do)
Hello. This is our team. Today we're introducing an installation case for a gas leak detector used with sterilizers tha
FIX800 Gas Detector Installation for CO2, O2, and N2 (via O2 Depletion) Monitoring — Laboratory/Research Facility (Gyeonggi-do, Jeolla-do)
Hello. This is our team. The installation case we're sharing today involves a FIX800 gas detector installed at a laborat
FIX800 Oxygen (O₂) Detector and Digital Display Board Installation — Confined-Space Septic Tank Room, Department Store (Gyeongsangnam-do)
Hello. Today's post may be one of the most useful field application cases we have shared so far. We have occasionally re